A weak circuit management cable if you may pull away sufficient distance from the power cable, or laid in the steel pipe, might make the exterior electrical interference diminished to the permissible limit. It is advisable to use management cables with steel shielding to forestall electrical interference that can produce misoperation of low-stage signal circuits or make insulation breakdown and other effects. A 220KV substation had a short circuit in the first system, because of the grounding community potential rise leading to the breakdown of the management cable insulation. The follow has proved that the control cable in a spare core grounding. 2. High-degree analog signal, it is suitable to use the full shield on the core, if obligatory, additionally accessible on the core of the sub-shield. 1. Switching signal, obtainable total shielding. Metal shielding is a vital measure to attenuate and prevent electrical interference. For different control cable shields, when the electromagnetic induction interference is bigger, it is appropriate to use two points of grounding. 3. Double shielding or compound total shielding of the inside shield layer is acceptable to use as a point of grounding, while the outer shield layer might be two factors of grounding. Including the total shielding of the core, sub-shield, and double-layer complete shielding.

Low-voltage energy line because of its larger load present, so generally first choose the cross-part in keeping with the heat conditions. Low-voltage lighting line due to its greater necessities for voltage degree, can first choose the part in response to the allowable voltage loss situations, after which take a look at the thermal conditions and mechanical power. 2. Ultra-High Voltage Distribution Device Control Cable Selection. Control cable metal shielding type choice needs to be generated by the potential power of the influence of electrical interference. 4. Number of two-level grounding ought to even be thought of in the position of transient present, the shield won’t be burned. A centralized one-point grounding can keep away from ground loop currents. When a single-section floor fault occurs in the first system. The explanation relies on the requirement to make sure the traditional operation of the computer monitoring system. In addition to the pc monitoring, the system control cable shield solely allows a concentrated point of grounding. In the computer control system of the analog signal circuit of the management cable shield, it is appropriate to use a centralized grounding. When the excessive-voltage energy distribution gadget for no-load line or transformer operation, resulting from electromagnetic induction, electrostatic induction and grounding community potential rise.